Answers are grounded in this paper and cite their sources.
Tsunami flows can result in the loss of life and infrastructure, which hampers the livelihood of coastal communities. In comparison to the conventional mitigation structures, which reduce the conveyance to the shore, buffer blocks can serve as a cost-effective method for attenuating the extreme flows, such as tsunamis and storm surges. They ensure unobstructed access to the shoreline. However, systematic experimental studies focusing on the various configurations and the analytical evaluation of the flow depth at the buffer block position remain limited. In this study, we present an experimental investigation of tsunami-like flows with various buffer block configurations. The number of rows was added in the staggered arrangement within the height limitation to assess their effectiveness under the same inflow conditions. In addition, the flow characteristics in the quasi-steady region with the Froude number ranging from 1 to 1.5 are analysed, through which empirical equations are proposed to evaluate the flow depth at the buffer block position, which helps in the design of such a structure. The findings indicate that the three-row configuration results in a maximum reduction of the momentum flux by 40%−60% for the tested inflow conditions.
No takes yet. Share an insight, caveat, or question.
Percy et al. (2026) studied this question.