Key result
Contactless mm-wave radar combined with neural networks achieves ~75% accuracy for detecting arrhythmias.
Why the study?
Does a 77 GHz FMCW mm-wave radar system combined with a 3-layer artificial neural network accurately monitor vital signs and detect cardiac arrhythmia compared to reference devices and ECG databases?
Does a 77 GHz FMCW mm-wave radar system combined with a 3-layer artificial neural network accurately monitor vital signs and detect cardiac arrhythmia compared to reference devices and ECG databases?
This feasibility study demonstrates that a 77 GHz FMCW mm-wave radar coupled with Fourier series signal reconstruction and a 3-layer neural network can non-invasively estimate heart rate within ±4 bpm of a reference cuff and classify arrhythmia with 75% test accuracy.
Answers are grounded in this paper and cite their sources.
Preliminary radar-based arrhythmia detection warrants clinical caution; leaves open larger prospective validation before adoption.
A non-contact, non-invasive monitoring system to measure and estimate the heart and breathing rate of humans using a frequency-modulated continuous wave (FMCW) mm-wave radar at 77 GHz is presented. A novel diagnostic system is proposed which extracts heartbeat phase signals from the FMCW radar (reconstructed using Fourier series analysis) to test a three-layer artificial neural network model to predict the presence of arrhythmia in individuals. The effect of person orientation, distance of measurement and movement was analyzed with respect to a reference device based on statistical measures that include number of outliers, mean, mean squared error (MSE), mean absolute error (MAE), median absolute error (medAE), skewness, standard deviation (SD) and R-squared values. The individual oriented in front of the radar outperformed almost all other orientations for most distances with an expected d = 90 cm and d = 120 cm. Furthermore, it was found that the heart rate that was measured while walking and the breathing rate which was measured for a motionless individual generated results with the lowest SD and MSE. An artificial neural network (ANN) was trained using the MIT-BIH database with a training accuracy of 93.9 % and an R2 value = 0.876. The diagnostic tool was tested on 15 subjects and achieved a mean test accuracy of 75%.
No takes yet. Share an insight, caveat, or question.
Iyer et al. (2022) studied Cardiac arrhythmia and vital signs monitoring (n=15). 77 GHz frequency-modulated continuous wave (FMCW) mm-wave radar (TI IWR1443BOOST) with a 3-layer artificial neural network (ANN) vs. Cuff-based OMRON reference device and MIT-BIH database ECG recordings was evaluated on Mean test accuracy for arrhythmia classification. FMCW mm-wave radar combined with a 3-layer artificial neural network achieved a 75% mean test accuracy for classifying arrhythmia across 15 subjects and estimated heart rate within ±4 bpm of the OMRON reference.