Key result
The presence of an OCT catheter in a biorestorative coronary bypass graft with an endoluminal flap stabilized local flow, resulting in a lower median oscillatory shear index (0.02384) compared to when the catheter was withdrawn (0.02635, p < 0.0001).
Why the study?
The implications of endothelial shear stress in bypass grafts, particularly in synthetic biorestorative coronary artery bypass grafts, remain unclear.
Does the presence of an OCT catheter affect the local hemodynamic forces (ESS and OSI) around an endoluminal flap in a biorestorative bypass graft in an ovine model?
Does the presence of an OCT catheter affect the local hemodynamic forces (ESS and OSI) around an endoluminal flap in a biorestorative bypass graft in an ovine model?
Absolute Event Rate: 0.02384% vs 0.02635%
p-value: p=<0.0001
CFD analysis derived from OCT and angiography reveals that an endoluminal flap in a bioresorbable bypass graft causes significant flow disturbances, which are exacerbated upon catheter withdrawal.
Supports preclinical ESS evaluation in biorestorative grafts; leaves open translation to clinical CABG.
Endothelial shear stress (ESS) plays a key role in the clinical outcomes in native and stented segments; however, their implications in bypass grafts and especially in a synthetic biorestorative coronary artery bypass graft are yet unclear. This report aims to examine the interplay between ESS and the morphological alterations of a biorestorative coronary bypass graft in an animal model. Computational fluid dynamics (CFD) simulation derived from the fusion of angiography and optical coherence tomography (OCT) imaging was used to reconstruct data on the luminal anatomy of a bioresorbable coronary bypass graft with an endoluminal "flap" identified during OCT acquisition. The "flap" compromised the smooth lumen surface and considerably disturbed the local flow, leading to abnormally low ESS and high oscillatory shear stress (OSI) in the vicinity of the "flap". In the presence of the catheter, the flow is more stable (median OSI 0.02384 versus 0.02635, p < 0.0001; maximum OSI 0.4612 versus 0.4837). Conversely, OSI increased as the catheter was withdrawn which can potentially cause back-and-forth motions of the "flap", triggering tissue fatigue failure. CFD analysis in this report provided sophisticated physiological information that complements the anatomic assessment from imaging enabling a complete understanding of biorestorative graft pathophysiology.
No takes yet. Share an insight, caveat, or question.
Poon et al. (2023) studied Coronary artery bypass grafting (n=1). OCT catheter presence vs. Absence of OCT catheter was evaluated on Median oscillatory shear index (OSI) (p=<0.0001). The presence of an OCT catheter in a biorestorative coronary bypass graft with an endoluminal flap stabilized local flow, resulting in a lower median oscillatory shear index (0.02384) compared to when the catheter was withdrawn (0.02635, p < 0.0001).