Key result
A novel AF scanning algorithm integrating rhythm and P-wave information achieved a detection accuracy ranging from 88.75% to 99.33% in patients with 24-hour paroxysmal atrial fibrillation.
An AF scanning algorithm integrating rhythm and P-wave information improves the specificity of paroxysmal AF detection in long-term ECGs compared to rhythm-only detectors.
May aid algorithm development for paroxysmal AF detection; leaves open prospective validation before clinical use.
Atrial fibrillation (AF) is a progressive disease often initially manifested by intermittent episodes spontaneously terminating and is an insidious disease. The previous work trained the support vector machine (SVM) classifier on multiple RR interval features. The trained AF detector was tested on the fourth China Physiological Signal Challenge (CPSC 2021) database, achieving 97.59% and 89.83% for sensitivity and specificity on dataset 1, respectively. The test results were 96.46% and 78.64% on dataset 2, respectively. The results show that the AF detector based on rhythm is insufficient for the recognition of non-AF. Therefore, this work developed AF scanning algorithm integrating rhythm and P-wave information for long-term ECGs. The proposed algorithm is divided into three steps. First, utilizeaprioriknowledge to locate suspected AF, and then, employ a trained rhythm-based AF detector to detect AF. Finally, adopt the dynamic time warping (DTW) and an autoencoding (AE) network to quantize the P-wave information to identify the non-AF signal from AF. The results on dataset 1 were 97.44% and 98.50% and on dataset 2 were 96.13% and 87.42%. This work scanned 11 patients with 24-h paroxysmal AF (PAF). The best result is that the detection accuracy is 99.33%, and the false detection is 0.01%, and the worst outcome is that the detection accuracy is 88.75%, and the false detection is 14.06%. The results proved that the proposed method could provide reliable scanning for PAF events.
No takes yet. Share an insight, caveat, or question.
Ma et al. (2022) studied Paroxysmal Atrial Fibrillation (n=11). AF scanning algorithm integrating rhythm and P-wave information vs. Rhythm-based AF detector was evaluated on Detection accuracy for paroxysmal AF. A novel AF scanning algorithm integrating rhythm and P-wave information achieved a detection accuracy ranging from 88.75% to 99.33% in patients with 24-hour paroxysmal atrial fibrillation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: