Key result
PulseSelect pulsed field ablation achieves 100% acute pulmonary vein isolation with zero serious adverse events.
Why the study?
Pulsed field ablation is a novel modality using electrical fields to ablate cardiac tissue, but limited data exist regarding its feasibility and safety in humans.
Does pulsed field ablation achieve acute pulmonary vein isolation safely in patients with paroxysmal or persistent atrial fibrillation?
Does pulsed field ablation achieve acute pulmonary vein isolation safely in patients with paroxysmal or persistent atrial fibrillation?
Answers are grounded in this paper and cite their sources.
In this first-in-human study, pulsed field ablation was feasible and safe for achieving acute pulmonary vein isolation in patients with atrial fibrillation, with 100% acute success and no serious adverse events at 30 days.
BACKGROUND: Pulsed field ablation (PFA) is a novel form of ablation using electrical fields to ablate cardiac tissue. There are only limited data assessing the feasibility and safety of this type of ablation in humans. METHODS: PULSED AF (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF; https://www.clinicaltrials.gov; unique identifier: NCT04198701) is a nonrandomized, prospective, multicenter, global, premarket clinical study. The first-in-human pilot phase evaluated the feasibility and efficacy of pulmonary vein isolation using a novel PFA system delivering bipolar, biphasic electrical fields through a circular multielectrode array catheter (PulseSelect; Medtronic, Inc). Thirty-eight patients with paroxysmal or persistent atrial fibrillation were treated in 6 centers in Australia, Canada, the United States, and the Netherlands. The primary outcomes were ability to achieve acute pulmonary vein isolation intraprocedurally and safety at 30 days. RESULTS: Acute electrical isolation was achieved in 100% of pulmonary veins (n=152) in the 38 patients. Skin-to-skin procedure time was 160±91 minutes, left atrial dwell time was 82±35 minutes, and fluoroscopy time was 28±9 minutes. No serious adverse events related to the PFA system occurred in the 30-day follow-up including phrenic nerve injury, esophageal injury, stroke, or death. CONCLUSIONS: In this first-in-human clinical study, 100% pulmonary vein isolation was achieved using only PFA with no PFA system-related serious adverse events. Graphic Abstract: A graphic abstract is available for this article.
No takes yet. Share an insight, caveat, or question.
A 2021 study studied Paroxysmal or persistent atrial fibrillation (n=38). Pulsed field ablation (PulseSelect system) was evaluated on Acute pulmonary vein isolation intraprocedurally and safety at 30 days. Pulsed field ablation using the PulseSelect catheter achieved 100% acute pulmonary vein isolation (152/152 veins) with 0% device-related serious adverse events at 30 days.