Why the study?
Does the Fitbit Charge 2 accurately measure heart rate compared to a gold standard electrocardiograph in healthy adults?
Does the Fitbit Charge 2 accurately measure heart rate compared to a gold standard electrocardiograph in healthy adults?
The Fitbit Charge 2 underestimates heart rate during cycling and has poor precision for individual measurements, limiting its utility for accurate clinical or fitness monitoring.
Answers are grounded in this paper and cite their sources.
Caution advised for Fitbit heart rate data in clinical decisions; leaves open accuracy of consumer wearables pending further validation.
Fitness trackers are devices or applications for monitoring and tracking fitness-related metrics such as distance walked or run, calorie consumption, quality of sleep and heart rate. Since accurate heart rate monitoring is essential in fitness training, the objective of this study was to assess the accuracy and precision of the Fitbit Charge 2 for measuring heart rate with respect to a gold standard electrocardiograph. Fifteen healthy participants were asked to ride a stationary bike for 10 minutes and their heart rate was simultaneously recorded from each device. Results showed that the Fitbit Charge 2 underestimates the heart rate. Although the mean bias in measuring heart rate was a modest -5.9 bpm (95% CI: -6.1 to -5.6 bpm), the limits of agreement, which indicate the precision of individual measurements, between the Fitbit Charge 2 and criterion measure were wide (+16.8 to -28.5 bpm) indicating that an individual heart rate measure could plausibly be underestimated by almost 30 bpm.
No takes yet. Share an insight, caveat, or question.
Caldato et al. (2018) studied this question.