Why the study?
Standard transthoracic echocardiography is the non-invasive gold standard for diagnosing most cardiac diseases, making it imperative to define its reproducibility, repeatability, and reliability to reduce clinical errors.
In dogs, echocardiographic measurements of the left ventricular internal diameters and aortic root are highly reliable across operators, whereas M-mode measurements of the interventricular septum and free wall show poor inter-operator reproducibility.
Answers are grounded in this paper and cite their sources.
Intra-operator reproducibility of canine echocardiographic parameters is generally good; leaves open standardization needs for inter-operator consistency in practice.
Standard transthoracic echocardiography is considered the non-invasive gold standard for the diagnosis of most cardiac diseases. Defining reproducibility, repeatability, and reliability of this exam is imperative to reduce errors in clinical evaluations. The present study aimed at: 1) evaluating the reproducibility and repeatability of 15 echocardiographic parameters in dogs by analyzing measurements obtained from several operators with different levels of experience and comparing them to the ones obtained from two board-certified operators (gold standards - GSs); 2) assessing whether different formative paths have an influence on the variability of the echocardiographic measurements. Fifty-one operators have been included in this study, along with two diplomates of the European College of Veterinary Internal Medicine - Cardiology. Ten dogs were enrolled, 5 Golden Retrievers and 5 Cavalier King Charles Spaniels. Echocardiographic examination was performed on each dog by one GS and several operators on the same day. Results show that M-mode measurements of the interventricular septum and the left ventricular free wall are the least reliable ones since they show a high deviation from the GS and a poor inter-operator reproducibility. Differently, M-mode-obtained internal diameters of the left ventricle in systole and diastole, and measurements of the aortic annulus and root are the most reliable echocardiographic parameters, demonstrating that all the operators can correctly assess left ventricular systolic function and dilation, and evaluate the aortic valve. Furthermore, a specialist clinical activity, more than the acquired theoretical knowledge, affects the reliability of the echocardiographic examination by reducing the difference from the GS’ measurements.
No takes yet. Share an insight, caveat, or question.
Ghilardi et al. (2023) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: