Laboratory specialists have been demonstrated that 70% of errors occur in the pre-analytical phase which is an important service of laboratory medicine. If the occurrence of error is manmade then it can always be identified and reduced. As the hospital management needs to evaluate the quality of laboratory services by knowing the sample rejection rate. A descriptive study was conducted to investigate and reduce the rejection rate for the Biochemistry and haematology samples received in the clinical laboratory. A strategy used in the study for the source detection of Failure modes are a) Brainstorming, b) Fish-bone diagram, c) Pareto’s chart, d) Failure Mode and Effect Analysis (FMEA) is an aid to calculate Risk Priority Number (RPN) that is the product of Occurrence Index (O.I), and Detectability Index (D.I). The total number of samples (both from OP & IP-D) received in the laboratory during the study period from January 2018 to April 2019 is about 3, 81,452 samples. The total number of samples rejected by the laboratory is 182 (0.047%). The highest rates according to Pareto’s principle & FMEA analysis are found for the failure modes sample clot,
No takes yet. Share an insight, caveat, or question.
A 2019 study studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: