Why the study?
Do carotid arterial interadventitial and lumen diameters differ between patients with documented coronary artery disease and disease-free controls?
Do carotid arterial interadventitial and lumen diameters differ between patients with documented coronary artery disease and disease-free controls?
Internal carotid artery lumen and interadventitial diameters are smaller in patients with coronary artery disease compared to healthy controls, highlighting segment-specific differences in arterial remodeling.
Answers are grounded in this paper and cite their sources.
Smaller carotid diameters in CAD may reflect shared remodeling; leaves open predictive value and clinical utility pending longitudinal data.
BACKGROUND: Although atherosclerosis often leads to lumen narrowing and symptomatic cardiovascular disease, it is now recognized that arteries have the potential to compensate by enlarging in response to atherosclerosis. We tested the hypotheses that carotid arterial interadventitial (IA) and lumen diameters were related to wall thickness and that carotid arterial diameters of individuals with coronary artery disease (CAD) differed from those of CAD-free controls. METHODS AND RESULTS: We measured lumen diameter, IA diameter, and intima-media thickness (IMT) using B-mode ultrasound in the common and internal carotid arteries of 141 CAD case patients and 139 disease-free control subjects. Common carotid IA diameter was greater in CAD cases than controls after adjustment for age, height, and sex (P<0.01). Common carotid lumen diameter was marginally larger in individuals with greater IMT (P=0.06) but was not associated with case status. Conversely, mean internal carotid IA and lumen diameters were smaller in CAD cases than controls in both univariable and multivariable models (both P<0.001), and lumina were smaller in individuals with greater IMT. Despite these cross-sectional differences in carotid artery dimensions, we were unable to detect any statistically significant interactive effects of CAD case status on the association of IMT with arterial dimensions. CONCLUSIONS: Internal carotid artery lumen and IA diameters are both smaller in CAD cases than controls. The association of increased IMT with arterial dimensions varies in a manner that is segment-specific for the common and internal carotid arteries.
No takes yet. Share an insight, caveat, or question.
Terry et al. (2003) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: