Why the study?
Does the 'figure-of-eight' suture reduce time to hemostasis and access site complications compared to manual compression in patients undergoing cryoablation?
Population
200 patients with symptomatic atrial fibrillation undergoing initial cryoablation procedure, anticoagulated…
Comparison
'Figure-of-eight' suture for immediate closure… vs Conventional manual compression.
Design
Cohort
Follow-up
3 months
Authors
Loading...
Supports figure-of-eight suture for rapid hemostasis after large-bore access in anticoagulated patients; leaves open randomized confirmation of complication reduction.
Does the 'figure-of-eight' suture reduce time to hemostasis and access site complications compared to manual compression in patients undergoing cryoablation?
The 'figure-of-eight' suture is a simple, safe, and highly effective technique for achieving immediate hemostasis after removal of large-bore (15-Fr) femoral venous sheaths in fully anticoagulated patients undergoing cryoablation.
Aytemir et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: