A method is described for determinations of cell and plasma volumes using Cr51 and I131 simultaneously in which hematocrit tubes are used for counting and separation of cells and plasma. In vitro determinations of volumes of blood were within 1% of actual volumes. Volumes and distributions found by this method in 4 goats are within the range of values found in the goat by other methods. Limitations of the method are also discussed.