Why the study?
Few safety data exist comparing clinical outcomes between Australian public and private hospitals, where differences in acuity and patient-level comorbidities could affect outcomes.
Does CIED placement in private hospitals compared to public hospitals affect the risk of major complications in adults?
Does CIED placement in private hospitals compared to public hospitals affect the risk of major complications in adults?
Overall major CIED-related complications are similar between Australian public and private hospitals, though specific complication types such as in-hospital mortality and post-discharge infection vary.
Similar overall CIED complication risk across sectors; leaves open acuity-adjusted mortality and infection differences for prospective confirmation.
BACKGROUND: Few safety data exist comparing clinical outcomes in Australian public and private hospitals. We hypothesised that differences could exist between public and private hospitals due to differences in acuity and patient-level co-morbidities. AIMS: To report comparative complications of cardiac implantable electronic device (CIED) placement in public and private hospitals. METHODS: We conducted an observational cohort study of outcomes of patients aged >18 years from 2010 to 2015 undergoing a new permanent pacemaker (PPM), implantable cardioverter defibrillator (ICD) or cardiac resynchronisation therapy pacemaker or defibrillator (CRT-D/P) implant in NSW and Queensland public and private hospitals. The primary endpoint was major CIED-related complications occurring in-hospital or within 90 days of discharge. The independent effect of hospital sector was determined using multiple logistic regression, adjusting for covariates, including age, sex, co-morbidities and procedural acuity. RESULTS: A total of 32 364 new CIED implants (PPM 23 845, ICD 5361 and CRT-D/P 3158) were included (49% in private hospitals). Overall, 8.0% of private hospital procedures and 9.6% public hospital procedures experienced at least one complication. After adjustment, the overall risk of CIED complications was similar in private and public hospitals (OR: 0.92, 95% CI: 0.84-1.00, P = 0.06). In analysis of individual complications, adjusted all-cause in-hospital mortality was higher in private hospitals, (OR: 1.49, 95% CI: 1.03-2.16, P = 0.036) primarily driven by an excess mortality in acute cases. The adjusted risk of in-hospital generator operation (OR: 0.53, 95% CI: 0.30-0.94, P = 0.03) and post-discharge infection (OR: 0.61, 95% CI: 0.46-0.81, P < 0.001) was lower in private hospitals. CONCLUSIONS: These data identify important similarities and differences in safety outcomes of CIED implantation between Australian public and private hospitals.
No takes yet. Share an insight, caveat, or question.
Ganesan et al. (2019) studied this question.