On two occasions ten healthy men inhaled with maximally deep inhalations at 0.5 1/sec a test aerosol of 4 micron teflon particles tagged with 111In. Radioactivity in the lungs was measured a few min, 24 hr, and 2, 3, and 4 days after inhalation. Retention decreased greatly between the measurements performed a few min and 24 hr after inhalation, but was similar in measurements 1 to 4 days after inhalation. Among individuals, retention varied considerably 1 to 4 days after inhalation (by a factor of 2), but the retention in each individual subject was uniform. Measuring the retention of a radioactively tagged test aerosol 1 day after inhalation, and regarding this retention as alveolar deposition, might be of value in preventive measures against certain toxic dusts.
No takes yet. Share an insight, caveat, or question.
Camner et al. (1978) studied this question.