Why the study?
Renewal processes commonly face an inspection paradox caused by oversampling longer events, prompting evaluation of its effect on the perception of phase singularity lifetimes in cardiac fibrillation.
Visual inspection of phase movies in cardiac fibrillation systematically oversamples longer-lasting phase singularities due to an inspection paradox, which can be minimized by considering the overall distribution of lifetimes.
Accounting for inspection paradox needed to avoid overestimating PS lifetimes in fibrillation; leaves open effects on clinical rotor mapping.
Background and Objective: Renewal theory is a statistical approach to model the formation and destruction of phase singularities (PS), which occur at the pivots of spiral waves. A common issue arising during observation of renewal processes is an inspection paradox, due to oversampling of longer events. The objective of this study was to characterise the effect of a potential inspection paradox on the perception of PS lifetimes in cardiac fibrillation. Methods: A multisystem, multi-modality study was performed, examining computational simulations (Aliev-Panfilov (APV) model, Courtmanche-Nattel model), experimentally acquired optical mapping Atrial and Ventricular Fibrillation (AF/VF) data, and clinically acquired human AF and VF. Distributions of all PS lifetimes across full epochs of AF, VF, or computational simulations, were compared with distributions formed from lifetimes of PS existing at 10,000 simulated commencement timepoints. Results: In all systems, an inspection paradox led towards oversampling of PS with longer lifetimes. In APV computational simulations there was a mean PS lifetime shift of +84.9% (95% CI, ± 0.3%) ( p < 0.001 for observed vs overall), in Courtmanche-Nattel simulations of AF +692.9% (95% CI, ±57.7%) ( p < 0.001), in optically mapped rat AF +374.6% (95% CI, ± 88.5%) ( p = 0.052), in human AF mapped with basket catheters +129.2% (95% CI, ±4.1%) ( p < 0.05), human AF-HD grid catheters 150.8% (95% CI, ± 9.0%) ( p < 0.001), in optically mapped rat VF +171.3% (95% CI, ±15.6%) ( p < 0.001), in human epicardial VF 153.5% (95% CI, ±15.7%) ( p < 0.001). Conclusion: Visual inspection of phase movies has the potential to systematically oversample longer lasting PS, due to an inspection paradox. An inspection paradox is minimised by consideration of the overall distribution of PS lifetimes.
No takes yet. Share an insight, caveat, or question.
Jenkins et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: