This study investigates sliding-induced degradation in α/β-SiAlON composite ceramics using microcantilever bending tests to directly probe near-surface mechanical properties. Repeated sliding contact with a Si₃N₄ counter body produced a thin (~200 nm), dislocation-rich layer beneath the surface, accompanied by a pronounced reduction in microcantilever bending strength within the first ~10 2 passes, while the strength remained nearly unchanged up to 10 5 passes. TEM and HRTEM analyses revealed that dislocation accumulation occurred preferentially in β-SiAlON grains and involved both primary and secondary slip systems, forming a highly strained region with a dislocation density on the order of 10¹⁴ m⁻². Fracture toughness measurements combined with Griffith-type analysis showed that the effective flaw size increased from ~50 nm to ~150 nm after sliding, consistent with the thickness of the dislocation-rich layer. In contrast, macroscopic three-point bending strength remained unaffected, indicating that sliding-induced defects are too small to dominate fracture in large stressed volumes. These findings demonstrate that microscale mechanical testing is essential for evaluating localized degradation in ceramics and provide new insight into the dislocation-based mechanisms governing sliding-induced weakening.