Why the study?
There are no absolute criteria guiding cerebral embolic protection device placement during transcatheter aortic valve replacement, and its impact on postoperative cerebrovascular events in high-risk patients remained to be evaluated.
Does cerebral embolic protection reduce cerebrovascular events in high-risk patients undergoing transcatheter aortic valve replacement?
Does cerebral embolic protection reduce cerebrovascular events in high-risk patients undergoing transcatheter aortic valve replacement?
In high-risk patients undergoing TAVR, cerebral embolic protection safely and significantly reduced the incidence of in-hospital cerebrovascular events and the combined endpoint of early mortality and stroke.
Supports selective CEP consideration in high-risk TAVR; leaves open efficacy confirmation by randomized trials.
Objectives: The sentinel cerebral embolic protection device has been used as prophylaxis of stroke and transient ischemic attack during transcatheter aortic valve replacement. However, there are no absolute criteria guiding cerebral embolic protection device placement. This study aimed to evaluate the impact of cerebral embolic protection on postoperative cerebrovascular events in patients at high risk for stroke. Methods: Between April 2021 and August 2023, 695 patients underwent transcatheter aortic valve replacement through a transfemoral approach. The cerebral embolic protection device was placed at the beginning of transcatheter aortic valve replacement procedure when 1 of the following criteria was met preoperatively: bicuspid aortic valve, valve-in-valve procedure, or calcium score in computed tomography greater than 1000. Of 695 patients with transcatheter aortic valve replacement, 636 met the criteria. The cerebral embolic protection device was placed in 55% of patients (350/636, cerebral embolic protection group) and not placed in 45% of patients (286/636, non-cerebral embolic protection group) because cerebral embolic protection was not feasible anatomically. A 1:1 propensity score matching was performed using the nearest neighbor method between cerebral embolic protection and non-cerebral embolic protection groups. Results: .62). There was no vascular complication at the cerebral embolic protection access site. Conclusions: Cerebral embolic protection during transcatheter aortic valve replacement might reduce postoperative cerebrovascular events in patients who are high risk for stroke in this patient cohort.
No takes yet. Share an insight, caveat, or question.
A 2025 study studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: