Answers are grounded in this paper and cite their sources.
Here, we report a double-amplified sensing platform for ultrasensitive chemiluminescence (CL) miRNA detection in real patients’ blood in which a hemin-bridged metal–organic framework (MOF) is employed as a functional interface to boost the payload and catalysis of G-quadruplex (G4) DNAzymes. Hemin is here used as the organic ligand for the MOF synthesis, which endows the MOF with an intrinsic peroxidase-like catalytic activity. Most importantly, the MOF surface provides a large amount of binding sites for polymeric G4 DNAzymes that are produced by miRNA-triggered rolling circle amplification reactions, and meanwhile, the interfaced G4 DNAzymes on MOFs (G4/MOFzymes) display an about 100-fold higher catalytic activity than those in solution. By using the G4/MOFzyme catalysts in the luminol/H 2 O 2 CL system, the amplification detection of two acute myocardial infarction (AMI)-related miRNAs (low to 1 fM seen with naked eyes) is achieved in human serum with a smartphone as a portable imaging detector, which provides a facile methodology for point-of-care (POC) diagnosis of AMI. Compared with previous smartphone-based counterparts not requiring sophisticated equipment, this new facile methodology shows both 6 orders of magnitude higher sensitivity and an ∼50-fold longer duration for CL miRNA imaging. These unique features allow our developed G4/MOFzymes to be further employed as a novel luminescent ink for printing commonly used patterns.
No takes yet. Share an insight, caveat, or question.
Mi et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: