Why the study?
Although heart rate variability is widely studied in type 2 diabetes mellitus, the impact of artefact correction methods remains underexplored.
Do different artefact correction filters in Kubios software affect short-term heart rate variability parameters in adults with type 2 diabetes mellitus?
Do different artefact correction filters in Kubios software affect short-term heart rate variability parameters in adults with type 2 diabetes mellitus?
Excessively restrictive artefact correction filtering in HRV analysis software significantly alters autonomic metrics in patients with T2DM, highlighting the need for standardized methodologies.
Answers are grounded in this paper and cite their sources.
May bias HRV metrics in T2DM with very strong correction; leaves open optimal Kubios standardization for autonomic research.
Heart rate variability (HRV) is a clinical marker used to assess autonomic function, and the application of filtering algorithms may significantly influence data quantification and interpretation. Although HRV has been extensively studied in individuals with type 2 diabetes mellitus (T2DM), the impact of artefact correction methods remains underexplored. To evaluate the effects of different artefact correction filters in Kubios software on short-term HRV parameters in individuals with T2DM. This cross-sectional, descriptive, and observational study included adults (≥ 18 years) diagnosed with T2DM. Anthropometric and metabolic data were collected, including fasting blood samples for glucose, insulin, and lipid profiles. HRV indices were analyzed across time-domain, frequency-domain, nonlinear, and global metrics. Statistical analysis was performed using ANOVA or Friedman tests according to data distribution, with significance set at p < 0.05. The sample consisted of 52 individuals (67% male, mean age 52 ± 8 years, mean BMI 29.65 ± 5.50 kg/m²). The median duration of T2DM was 3 years (IQR 1.5–10). Median metabolic parameters were insulin 12.50 µU/mL, triglycerides 141.50 mg/dL, fasting glucose 149.50 mg/dL, and HbA1c 8.65% (IQR 7.20–10.00). Application of the most restrictive artefact correction setting (“very strong”) in Kubios significantly modified overall HRV as well as time-domain, frequency-domain, and nonlinear parameters (p < 0.05), highlighting its influence on HRV quantification. This study demonstrates that artefact correction filters, particularly the “very strong” setting, substantially affect HRV analysis in individuals with T2DM. Excessively restrictive filtering may distort autonomic metrics and potentially bias interpretation. Standardization of artefact correction methods is essential to ensure accurate and reproducible HRV assessment in clinical and research settings.
No takes yet. Share an insight, caveat, or question.
Bassi-Dibai et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: