Why the study?
Is the LVD-36 a reliable, valid, and responsive health status measure for patients with left ventricular dysfunction?
Is the LVD-36 a reliable, valid, and responsive health status measure for patients with left ventricular dysfunction?
The LVD-36 is a reliable, valid, and responsive short questionnaire for assessing health status in patients with left ventricular dysfunction.
Answers are grounded in this paper and cite their sources.
LVD-36 shows reliability and validity in left ventricular dysfunction; supports its use as a measure but leaves open responsiveness and clinical adoption pending further study.
OBJECTIVE: To examine the reliability, validity, and responsiveness of a new health status measure (LVD-36) for patients with left ventricular dysfunction which was designed with emphasis on content validity, clarity, brevity, and ease of use. DESIGN: At baseline, patients completed the LVD-36 and a range of measures reflecting general health and disease severity. The LVD-36 was repeated after one week. After six months, it was repeated again, along with a transition question to measure global changes in health. SETTING: Patients were recruited from the cardiology and general medical clinics at a south west London hospital. PATIENTS: 60 patients with chronic left ventricular dysfunction. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Short form 36 questionnaire (SF-36), Minnesota living with heart failure questionnaire (LIhFE), New York Heart Association criteria, and exercise performance and echocardiographic tests. RESULTS: The LVD-36 showed good internal consistency (kappa = 0.95) and repeatability (r(i) = 0.95). Its scores were significantly associated with SF-36 mental and physical component scores (r = -0. 48 and -0.75; p < 0.0001), with exercise capacity (r = -0.52; p < 0. 0001), and with systolic shortening fraction (r = -0.27; p < 0.05). Change in the LVD-36 over six months was associated with change in overall health (F = 5.7; p < 0.001). In tests of validity and responsiveness, the LVD-36 performed similarly to or marginally better than the LIhFE. CONCLUSIONS: The LVD-36 showed a high level of reliability and validity, and appears to measure changes in health. It provides a short, simple, valid, and reliable measure of health status in patients with left ventricular dysfunction.
No takes yet. Share an insight, caveat, or question.
Catherine O’Leary (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: