Ensuring caprock integrity is essential for ensuring the safety of long-term CO 2 storage, particularly in faulted formations. As part of the Carbon Sequestration, Series-E (CS-E) experiment at the Mont Terri Rock Laboratory, we acquired new cross-hole seismic data using both cemented geophones and fibre-optic Distributed Acoustic Sensing (DAS) to image a clay-rich fault zone at metre scale. We developed a workflow for extracting first-arrival travel times from DAS data without trigger timing, including data-based shot timing, denoising, and anisotropy correction, and applied the same tomographic inversion used for geophones. As DAS was permanently installed in multiple boreholes, it could also be used to illuminate other planes with the same shot series. Both sensing systems resolve a low-velocity zone coincident with the mapped Main Fault. Despite a lower signal-to-noise ratio and larger zero-timing uncertainty, DAS produces tomograms comparable to the geophones because of its dense spatial sampling and broad ray coverage. The DAS-based models exhibit higher residuals but reliably capture the principal fault-zone structure, demonstrating that DAS can be used for static high-density seismic imaging of metre-scale structures in clay-rich caprock. Our results confirm that DAS is a practical and complementary tool to geophones for borehole seismic monitoring in caprock settings, particularly in CO 2 storage where long-term durability and multi-borehole coverage are required.
No takes yet. Share an insight, caveat, or question.
Tuinstra et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: