Both formalin and methanol fixation protocols should be used for comprehensive detection of cardiac ion channels by immunolabelling in rat myocytes.
Answers are grounded in this paper and cite their sources.
Fixation choice determines detectable cardiac ion channels in rat myocytes; leaves open optimal protocols for human immunolabelling studies.
In this study, a fixation protocol using a 10% neutral buffered formalin (FA) solution and another protocol using a methanol (MeOH) solution were compared for detection of ion channels, Kv1.5, Kv4.2, Cav1.2, Kir6.2, Nav1.5 and Nav1.1 in rat myocytes by immunolabelling. Kv1.5 and Kv4.2 at intercalated discs and Cav1.2 at transverse tubules were not detected by FA but were detected by MeOH. Kir6.2 at transverse tubules and Nav1.5 at sarcolemma were detected by FA but not by MeOH. It is suggested that both FA and MeOH fixation protocols should be used for the detection of cardiac ion channels by immunolabelling.
No takes yet. Share an insight, caveat, or question.
Yamanushi et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: