Key result
An image-based immersed boundary model of the aortic root successfully generated physiological pressures, realistic cardiac output, and fully competent valve dynamics without regurgitation.
A patient-specific computational model of the aortic root demonstrates that while glutaraldehyde fixation alters diastolic leaflet deformation, it results in nearly identical hemodynamics compared to fresh leaflets.
Suggests glutaraldehyde fixation maintains hemodynamic performance despite altering leaflet deformation; leaves open whether these computational findings.
Each year, approximately 300,000 heart valve repair or replacement procedures are performed worldwide, including approximately 70,000 aortic valve replacement surgeries in the United States alone. Computational platforms for simulating cardiovascular devices such as prosthetic heart valves promise to improve device design and assist in treatment planning, including patient-specific device selection. This paper describes progress in constructing anatomically and physiologically realistic immersed boundary (IB) models of the dynamics of the aortic root and ascending aorta. This work builds on earlier IB models of fluid-structure interaction (FSI) in the aortic root, which previously achieved realistic hemodynamics over multiple cardiac cycles, but which also were limited to simplified aortic geometries and idealized descriptions of the biomechanics of the aortic valve cusps. By contrast, the model described herein uses an anatomical geometry reconstructed from patient-specific computed tomography angiography (CTA) data, and employs a description of the elasticity of the aortic valve leaflets based on a fiber-reinforced constitutive model fit to experimental tensile test data. The resulting model generates physiological pressures in both systole and diastole, and yields realistic cardiac output and stroke volume at physiological Reynolds numbers. Contact between the valve leaflets during diastole is handled automatically by the IB method, yielding a fully competent valve model that supports a physiological diastolic pressure load without regurgitation. Numerical tests show that the model is able to resolve the leaflet biomechanics in diastole and early systole at practical grid spacings. The model is also used to examine differences in the mechanics and fluid dynamics yielded by fresh valve leaflets and glutaraldehyde-fixed leaflets similar to those used in bioprosthetic heart valves. Although there are large differences in the leaflet deformations during diastole, the differences in the open configurations of the valve models are relatively small, and nearly identical hemodynamics are obtained in all cases considered.
No takes yet. Share an insight, caveat, or question.
Hasan et al. (2017) studied Aortic valve biomechanics. Image-based immersed boundary (IB) model vs. Fresh valve leaflets vs glutaraldehyde-fixed leaflets was evaluated on Hemodynamics and leaflet biomechanics. An image-based immersed boundary model of the aortic root successfully generated physiological pressures, realistic cardiac output, and fully competent valve dynamics without regurgitation.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: