Answers are grounded in this paper and cite their sources.
In motors containing magnets, irreversible demagnetization failure is one of the factors that negatively affect motor performance. In this study, the traditional Axial Flux Permanent Magnet Synchronous Motor (AF-PMSM) rotor structure was changed and the structure that gained the feature of starting from the line was used. Line Start AF-PMSM with 5.5 kW shaft power has 4 poles and each pole consists of 5 magnets. Demagnetization failure was obtained by the flux values of the magnets in any pole are drawn to zero and virtual demagnetization failure is created at certain rates (20%, 40% and 60%). With FEM, the data of the healthy and faulty motor were obtained. The data are then presented comparatively. Obtained data showed that demagnetization fault in Line Start AF-PMSM negatively affects motor performance, and the results are given in detail in the article. The original aspect of the study is that the demagnetization fault in Line Start AF-PMSM was investigated for the first time with FEM.
No takes yet. Share an insight, caveat, or question.
Eker et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: