Key result
Hospital experience with EVAR was associated with a significant decrease in in-hospital mortality and length of stay, whereas the learning curve for fEVAR was effectively flat.
Why the study?
Does accumulated hospital experience (learning curve) improve in-hospital mortality and length of stay for patients undergoing EVAR or fEVAR for unruptured abdominal aortic aneurysms?
Observational (n=40,000)
Yes
Does accumulated hospital experience (learning curve) improve in-hospital mortality and length of stay for patients undergoing EVAR or fEVAR for unruptured abdominal aortic aneurysms?
Hospital experience significantly improves mortality and length of stay for standard EVAR but not for fenestrated EVAR, demonstrating the need to incorporate learning curves into health technology assessments.
Answers are grounded in this paper and cite their sources.
May inform selective volume policies for EVAR but not fEVAR; leaves open learning-curve integration into health technology assessments.
Changes in performance due to learning may dynamically influence the results of a technology evaluation through the change in effectiveness and costs. In this study, we estimate the effect of learning using the example of two minimally invasive treatments of abdominal aortic aneurysms: endovascular aneurysm repair (EVAR) and fenestrated EVAR (fEVAR). The analysis is based on the administrative data of over 40,000 patients admitted with unruptured abdominal aortic aneurysm to more than 500 different hospitals over the years 2006 to 2013. We examine two patient outcomes, namely, in-hospital mortality and length of stay using hierarchical regression models with random effects at the hospital level. The estimated models control for patient and hospital characteristics and take learning interdependency between EVAR and fEVAR into account. In case of EVAR, we observe a significant decrease both in the in-hospital mortality and length of stay with experience accumulated at the hospital level; however, the learning curve for fEVAR in both outcomes is effectively flat. To foster the consideration of learning in health technology assessments of medical devices, a general framework for estimating learning effects is derived from the analysis.
No takes yet. Share an insight, caveat, or question.
Varabyova et al. (2017) conducted an observational in Unruptured abdominal aortic aneurysm (n=40,000). Hospital experience with endovascular aneurysm repair (EVAR) and fenestrated EVAR (fEVAR) was evaluated on In-hospital mortality and length of stay. Hospital experience with EVAR was associated with a significant decrease in in-hospital mortality and length of stay, whereas the learning curve for fEVAR was effectively flat.
Synapse has enriched 10 related papers. Consider them for comparative context: