Answers are grounded in this paper and cite their sources.
The design of a vortex tube of good efficiency in which the expansion of a gas in a centrifugal field produces cold is described. The important variables in construction and operation are discussed and data for several tubes under various operating conditions are given. Low pressure gas, 2 to 11 atmospheres, enters the tube and two streams of air, one hot and the other cold, emerge at nearly atmospheric pressure. The cold stream may be as much as 68°C below inlet temperatures. Efficiencies and applications are discussed.
No takes yet. Share an insight, caveat, or question.
R. Hilsch (1947) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: