Key result
EuroSCORE II and other conventional cardiac surgery risk scores demonstrated poor predictive ability for 30-day mortality in patients undergoing transcatheter aortic valve implantation, with EuroSCORE II yielding an AUC of 0.54.
Why the study?
Do established cardiac surgery risk scores accurately predict 30-day mortality in patients undergoing TAVI?
Observational (n=457)
No
Do established cardiac surgery risk scores accurately predict 30-day mortality in patients undergoing TAVI?
Effect estimate: AUC 0.54 (95% CI 0.46-0.63)
Established cardiac surgery risk scores, including EuroSCORE II and STS, fail to accurately predict 30-day mortality in patients undergoing TAVI, highlighting the need for TAVI-specific risk models.
Clinicians should not rely on EuroSCORE II for TAVI risk assessment; leaves open development of dedicated TAVI-specific models.
BACKGROUND: The logistic European System for Cardiac Operative Risk Evaluation (logEuroSCORE) II was developed to improve prediction of mortality in cardiac surgery. However, no specific tools are available for risk prediction in transcatheter aortic valve implantation (TAVI). The recently introduced EuroSCORE II was compared with established risk scores. PATIENTS AND METHODS: We assessed 457 consecutive patients (80.5 ± 7.1 years, 52.3% female) undergoing TAVI. Preoperative risk evaluation included logEuroSCORE I, EuroSCORE II, Society of Thoracic Surgeons (STS), Ambler, and Parsonnet scores. Validity was assessed by receiver-operating characteristic (ROC) and area under the curve (AUC). RESULTS: A 30-day mortality was 9.6% (44/457). Calculated scores were logEuroSCORE I 22.0%, confidence interval (CI) 21.0 to 24.6; EuroSCORE II 7.0%, CI 6.4 to 8.1; STS 7.9%, CI 7.7 to 9.5; Ambler score 6.9%, CI 5.7 to 7.0; and Parsonnet score 23.8%, CI 20.9 to 24.1. ROC analyses demonstrated no predictive value: logEuroSCORE I AUC 0.56, CI 0.47 to 0.65; EuroSCORE II AUC 0.54, CI 0.46 to 0.63; STS AUC 0.57, CI 0.49 to 0.66; Ambler AUC 0.52, CI 0.43 to 0.60; and Parsonnet AUC 0.51, CI 0.43 to 0.60. Accuracy and thresholds were measured on behalf of Youden index. Accuracy ranged between 44.2% (Parsonnet) and 66.3% (logEuroSCORE I). Thresholds were logEuroSCORE I 26%, EuroSCORE II 7%, STS 6%, Ambler 3%, and Parsonnet 19%. CONCLUSIONS: No risk evaluation system provided acceptable predictive ability. Scores derived from conventional cardiac surgery failed in risk prediction for TAVI. Specific risk tools are required. Until available, estimation of risk has to rely on judgment of an interdisciplinary heart team regarding individual patient factors.
No takes yet. Share an insight, caveat, or question.
Conradi et al. (2014) conducted an observational in Severe aortic stenosis (n=457). EuroSCORE II and established surgical risk scores was evaluated on Predictive ability for 30-day mortality (Area Under the Curve) (AUC 0.54, 95% CI 0.46-0.63). EuroSCORE II and other conventional cardiac surgery risk scores demonstrated poor predictive ability for 30-day mortality in patients undergoing transcatheter aortic valve implantation, with EuroSCORE II yielding an AUC of 0.54.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: