Key result
Treatment of acute Type A aortic dissection using the Thoraflex Hybrid prosthesis and the Frozen Elephant Trunk technique resulted in only 1 hospital mortality among 24 consecutive patients.
Why the study?
The authors sought to describe a safe and reproducible technique for aortic arch replacement using the Thoraflex Hybrid prosthesis in acute type A aortic dissection.
Observational (n=24)
No
The described 'Frozen Elephant Trunk' technique using the Thoraflex Hybrid prosthesis for acute type A aortic dissection demonstrated safety with only 1 hospital mortality in 24 patients.
Answers are grounded in this paper and cite their sources.
Supports further evaluation of Thoraflex FET in acute TAAD; hypothesis-generating and should not yet change practice.
Objectives: To describe our technique for the implantation of the Thoraflex Hybrid prosthesis for replacement of the aortic arch in a safe and reproducible way. Materials: Thoraflex™ Hybrid Plexus Device (Terumo Aortic). Design: Drawing on our own experience over the past 4 years in the management of acute type A aortic dissection, we have distilled the essentials of our “Frozen Elephant Trunk” technique which have led us through our own learning curve to the improved management of this taxing condition. Method/ Results: Small extension of the median sternotomy incision along the medial border of sternocleidomastoid muscle. End to side graft anastomosis near the origin of the left subclavian artery during cooling on bypass towards 20 degrees. Attention to cardiac protection and maintenance of cerebral perfusion during the shortened corporeal arrest period. Excellent results in 24 consecutive AAAD patients with just one hospital mortality. Conclusions: We believe we are entering a new phase in the treatment of AAAD, facilitated by the availability of a hybrid prosthesis which combines expanding stent technology with familiar surgical graft material. Our particular management of the left subclavian artery and of the cerebral circulation during implantation has contributed to an expeditious and reproducible method of treating dissection within the arch of the aorta and beyond.
No takes yet. Share an insight, caveat, or question.
Patronis et al. (2020) conducted an observational in Acute Type A Aortic Dissection (n=24). Thoraflex Hybrid Plexus Device (Frozen Elephant Trunk technique) was evaluated on Hospital mortality. Treatment of acute Type A aortic dissection using the Thoraflex Hybrid prosthesis and the Frozen Elephant Trunk technique resulted in only 1 hospital mortality among 24 consecutive patients.
Synapse has enriched 10 related papers. Consider them for comparative context: