Experimental study demonstrates restored input current symmetry in aircraft Vienna rectifiers during switch faults, indicating improved power system resilience.
In aircraft, the high dc component and even harmonics in the input current of the front-end Vienna rectifier during faults can easily trigger the generator to protect and interrupt the power supply. However, existing fault-tolerance control (FTC) methods cannot effectively reduce them. In this article, first, the impact of an open-circuit fault of a switch on the voltage vector is analyzed. The reason why existing FTC methods fail to improve the half-wave symmetry of input current (HWSIC) is also revealed. Then, a FTC method for improving the HWSIC is proposed. In this method, for areas affected by the fault, the offset voltages injected into the reference voltages are derived in detail. This involves accurately synthesizing the reference voltage vector (RVV) by replacing the infeasible vector with the redundant vector and approximately synthesizing RVV with only two available vectors. For areas unaffected by the fault, the offset voltages injected into the reference voltages are also discussed to achieve a completely symmetrical synthesis style of RVV in the positive and negative half-cycles of the current. As a result, good HWSIC can be obtained. Additionally, the total harmonic distortion of the input current and the ripple of the dc output voltage are reduced. Finally, the effectiveness of the proposed FTC method is verified through experiments.