Why the study?
Does serum troponin I measurement using an automated fluoroenzymometric assay improve diagnostic accuracy for acute myocardial infarction compared to traditional biochemical markers?
Does serum troponin I measurement using an automated fluoroenzymometric assay improve diagnostic accuracy for acute myocardial infarction compared to traditional biochemical markers?
Serum troponin I measured by fluoroenzymometric assay is a highly specific and sensitive marker for acute myocardial infarction, outperforming traditional markers in patients with skeletal muscle or renal disease.
Answers are grounded in this paper and cite their sources.
Supports troponin I at 4 hours for AMI diagnosis; leaves open superiority over traditional markers in broader use.
The aim of our study was to evaluate the clinical relevance of serum troponin I (TnI) as a marker of ischemic myocardial injury by using an automated fluoroenzymometric assay. The reference range for serum TnI was established by measuring serum TnI concentrations in blood from 75 healthy donors. The concentration was then compared with serum creatine kinase (CK) activity, CK-MB mass, and myoglobin concentrations in 20 patients with myocardial infarction diagnosed according to the WHO criteria, 20 patients with chest pain of nonischemic origin, 9 patients with unstable angina, 11 with stable angina, 11 patients with chronic muscular diseases, 6 patients with muscular trauma without chest contusion, and 13 patients with chronic renal disease. We found that: (a) 99% of the blood donors had TnI concentrations <0.26 microgram/L (detection limit of the assay in our study); (b) TnI values in acute myocardial infarction (AMI) patients 4 h after onset of chest pain showed a sensitivity of 0.769 and a specificity of 1.0 at a decisional concentration for AMI of 1 microgram/L, even in the presence of severe skeletal muscle injuries or renal diseases; (c) the increase in TnI concentrations after infarction (interquartile range 3.25-6 h) and the peak occurred later (interquartile range 11.5-24 h) than the rise found in myoglobin and CK-MB, but the increase persisted much longer (>96 h); (d) receiver-operating characteristic curve analysis showed the high diagnostic accuracy of TnI in diagnosing AMI even in patients in whom traditional biochemical markers are adversely influenced by underlying clinical situations.
No takes yet. Share an insight, caveat, or question.
Zaninotto et al. (1996) studied this question.