Key result
Pulsed-field ablation for atrial fibrillation had shorter procedure times (58 vs 83 min, p<0.001) and lower AF recurrence (9% vs 24%) compared to single catheter HPSD-RF ablation.
Why the study?
A direct comparison between pulsed-field ablation and single catheter high-power short-duration radiofrequency ablation for atrial fibrillation was lacking.
Does pulsed-field ablation improve procedural efficiency, safety, and AF-free survival compared to single catheter HPSD-RF ablation in patients with atrial fibrillation?
Cohort (n=119)
Does pulsed-field ablation improve procedural efficiency, safety, and AF-free survival compared to single catheter HPSD-RF ablation in patients with atrial fibrillation?
Absolute Event Rate: 9% vs 24%
Pulsed-field ablation for atrial fibrillation offers shorter procedure times and potentially improved AF-free survival compared to single catheter HPSD-RF ablation, despite longer fluoroscopy times and greater myocardial injury.
Comparable PVI efficiency and outcomes with either technique may support clinician choice in paroxysmal AF; leaves open need for randomized confirmation.
Funding Acknowledgements Type of funding sources: None. Background Pulsed-field ablation (PFA) has emerged as a novel treatment strategy for patients with atrial fibrillation (AF). A direct comparison to high-power short-duration (HPSD) radiofrequency (RF) ablation using a single catheter is lacking. Aim To compare pulmonary vein isolation (PVI) using PFA versus single catheter HPSD-RF ablation regarding efficiency, safety, myocardial injury, and outcomes. Methods 119 patients underwent PVI and were included (age 65.6 ± 10 years, ejection fraction 0.55 ± 0.11, left atrial size 41 ± 6.6 mm, paroxysmal AF 55%). 56 patients (47%) underwent PFA using a multi-electrode pentaspline PFA catheter with a biphasic waveform and 63 patients (53%) underwent single catheter HPSD-RF ablation without a multipolar mapping catheter. Results Using PFA the median procedure time was significantly shorter compared to the single catheter HPSD-RF group with 58 (IQR 51-70) min versus 83 (IQR 71-99) min (p<0.001), while fluoroscopic time was significantly longer with 12 (IQR 10-16) min versus 2.2 (IQR 1.3-3.6) min (p<0.001). First-pass isolation was achieved in 91% of the PFA group and 88% in the HPSD-RF group. 3.3 catheters vs. 1.0 catheters were used in the PFA group versus the HPSD-RF group, p<0.01. One procedural complications was observed in the PFA group and one complication in the HPSD-RF group (Tamponades). High sensitivity cardiac troponin levels were on average significantly higher in patients using the PFA system, 1520 (IQR 1010-1980) ng/l compared to 897 (IQR 725-1240) ng/l in the HPSD-RF group. During a median follow-up of 177 days (IQR 92-300), AF recurrence was observed in five patients (9%) from the PFA group and in 15 patients (24%) from the HPSD-RF group. (Figure 1) Conclusion PFA showed shorter procedure times but longer fluoroscopy times, higher levels of hs cTnT, and a possible improved AF-free survival.
No takes yet. Share an insight, caveat, or question.
Weidlich et al. (2023) conducted a cohort in Atrial fibrillation (n=119). Pulsed-field ablation (PFA) vs. Single catheter high-power short-duration (HPSD) radiofrequency (RF) ablation was evaluated on AF recurrence. Pulsed-field ablation for atrial fibrillation had shorter procedure times (58 vs 83 min, p<0.001) and lower AF recurrence (9% vs 24%) compared to single catheter HPSD-RF ablation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: