Key result
The implantable loop recorder enabled an arrhythmic or non-arrhythmic diagnosis in 65.2% of paediatric patients with recurrent syncope, presyncope, or palpitations.
Why the study?
Does the implantable loop recorder (ILR) provide a high diagnostic yield in pediatric patients with recurrent syncope, presyncope, or palpitations?
Cohort (n=23)
No
Does the implantable loop recorder (ILR) provide a high diagnostic yield in pediatric patients with recurrent syncope, presyncope, or palpitations?
Answers are grounded in this paper and cite their sources.
The implantable loop recorder provides a high diagnostic yield for identifying arrhythmic and non-arrhythmic causes of syncope and palpitations in pediatric patients.
The implantable loop recorder (ILR) has proved highly efficacious in the management of syncope, presyncope and palpitations in selected populations. Limited information regarding patient selection and diagnostic yield exists in the paediatric setting. A retrospective evaluation of patients who underwent ILR implantation over a 66-month period, in a tertiary paediatric cardiology unit was conducted. Twenty-three patients (10 male, 13 female) following initial assessment and investigation, were referred for device implantation. The mean age at time of ILR insertion was 11.39 +/- 4.34 (range, 2.0-16.8) years. The indications for ILR were recurrent syncope (n = 11), presyncope (n = 3) or palpitations (n = 9). Four (17.4%) patients had structural heart disease, three (13%) had a positive family history of sudden cardiac death and one (4%) had perinatal arrhythmia. One patient required ILR repositioning, and pocket infection necessitated explantation in one further patient. Minimum follow-up was 7.8 months during which symptoms were reported in 15 (65.2%) patients post-ILR insertion. Eight (34.7%) remained asymptomatic. Of the 15 who experienced symptom recurrence, eight (53.3%) had an arrhythmia recorded. Tachycardias recorded were polymorphic ventricular tachycardia (n = 1) and supraventricular tachycardia (n = 5). Clinically significant bradycardias documented, included sinus arrest (n = 1) and Mobitz type II second degree atrioventricular block (n = 1). The ILR had a high diagnostic yield, enabling an arrhythmic or non-arrhythmic diagnosis in 65.2% of patients with recurrent syncope, presyncope or palpitations in a selected paediatric population.
No takes yet. Share an insight, caveat, or question.
Babikar et al. (2007) conducted a cohort in Recurrent syncope, presyncope or palpitations (n=23). Implantable loop recorder (ILR) was evaluated on Arrhythmic or non-arrhythmic diagnosis (diagnostic yield). The implantable loop recorder enabled an arrhythmic or non-arrhythmic diagnosis in 65.2% of paediatric patients with recurrent syncope, presyncope, or palpitations.
Synapse has enriched 10 related papers. Consider them for comparative context: