Key result
A databased Fourier series approach combined with the Windkessel model was proposed and validated to correct oscillometric blood-pressure measurements in healthy, hypertensive, and hypotensive patients.
Why the study?
Does a Fourier series and Windkessel model-based calibration improve the accuracy of oscillometric blood-pressure measurements in patients with severe hyper- or hypotension?
Does a Fourier series and Windkessel model-based calibration improve the accuracy of oscillometric blood-pressure measurements in patients with severe hyper- or hypotension?
Applying a Windkessel model and Fourier series approach may offer a method to calibrate and correct oscillometric blood pressure measurements, particularly for patients with severe hyper- or hypotension where standard devices often fail.
Answers are grounded in this paper and cite their sources.
May enhance oscillometric BP accuracy in extreme ranges; hypothesis-generating and requires prospective validation before practice change.
Developing a good model for oscillometric blood-pressure measurements is a hard task. This is mainly due to the fact that the systolic and diastolic pressures cannot be directly measured by noninvasive automatic oscillometric blood-pressure meters (NIBP) but need to be computed based on some kind of algorithm. This is in strong contrast with the classical Korotkoff method, where the diastolic and systolic blood pressures can be directly measured by a sphygmomanometer. Although an NIBP returns results similar to the Korotkoff method for patients with normal blood pressures, a big discrepancy exist between both methods for severe hyper- and hypotension. For these severe cases, a statistical model is needed to compensate or calibrate the oscillometric blood-pressure meters. Although different statistical models have been already studied, no immediate calibration method has been proposed. The reason is that the step from a model, describing the measurements, to a calibration, correcting the blood-pressure meters, is a rather large leap. In this paper, we study a “databased” Fourier series approach to model the oscillometric waveform and use the Windkessel model for the blood flow to correct the oscillometric blood-pressure meters. The method is validated on a measurement campaign consisting of healthy patients and patients suffering from either hyper- or hypotension.
No takes yet. Share an insight, caveat, or question.
Barbé et al. (2011) studied Hyper- or hypotension. Windkessel model and databased Fourier series approach was evaluated. A databased Fourier series approach combined with the Windkessel model was proposed and validated to correct oscillometric blood-pressure measurements in healthy, hypertensive, and hypotensive patients.