Key result
Emergency replacement of the ascending aorta and resuspension of the aortic valve successfully treated cardiogenic shock caused by extremely localized aortic dissection and intussusception of the intimal flap.
Case Report (n=1)
No
Transesophageal echocardiography is a crucial diagnostic modality for identifying extremely localized aortic dissection causing severe aortic regurgitation and cardiogenic shock when computed tomography and transthoracic echocardiography are inconclusive.
Answers are grounded in this paper and cite their sources.
May guide surgical decisions in rare aortic dissection variants with shock; leaves open validation in larger cohorts.
Stanford type A aortic dissection frequently deforms the aortic root and causes aortic regurgitation (AR). On the rare occasion, massive AR can occur due to circumferential intimal disruption and prolapse of the cylinder-shaped intimal flap into the left ventricle. Because of the critical, general, and hemodynamic state of such patients, surgery for this condition carries a high risk. A 62-year-old woman suffered acute chest pain and fell into cardiogenic shock. Computed tomography and transthoracic echocardiography failed to identify the etiology of this rapid hemodynamic collapse. Transesophageal echocardiography (TEE) demonstrated circumferential intimal disruption, 3 centimeters above the aortic valve annulus; a very localized aortic dissection in the proximal ascending aorta; and a to-and-fro motion of cylinder-shaped intima causing severe AR. The dissection did not affect the aorta beyond the intimal tear, and TEE was the only useful modality for the diagnosis. Emergency replacement of the ascending aorta and resuspension of the aortic valve was successfully performed. Residual AR was absent, and the postoperative course was uneventful.
No takes yet. Share an insight, caveat, or question.
Yamabi et al. (2011) conducted a case report in Extremely localized aortic dissection and intussusception of the intimal flap (n=1). Emergency replacement of the ascending aorta and resuspension of the aortic valve was evaluated on Resolution of aortic regurgitation and survival. Emergency replacement of the ascending aorta and resuspension of the aortic valve successfully treated cardiogenic shock caused by extremely localized aortic dissection and intussusception of the intimal flap.
Synapse has enriched 10 related papers. Consider them for comparative context: