This is the authors' abstract. We don't add key points for this paper.
Herein, we examine the impact of Ga + ion kinetic energy and the target material type on the extent of ion implantation and structural damage in atomic force microscopy probes made of Al 2 O 3 and ZnO manufactured by focused ion beam using scanning transmission electron microscopy and energy-dispersive X-ray mapping. Penetration of Ga into the Al 2 O 3 lattice induced structural distortions and amorphization. For the ZnO probes, Ga is uniformly dispersed across the surface, resulting in the formation of distinct clusters. Atom probe tomography further validates the Ga distributions in Al 2 O 3 and ZnO nanoprobes. Complementary Monte Carlo simulations with the transport of ions in the matter program indicated that the introduction of Ga + prompts the generation of cation and anion vacancies, an occurrence more pronounced in Al 2 O 3 compared to ZnO. This study not only enriches the knowledge of ion–matter interactions but also serves as a practical guide for the fabrication of nanoscale functionalized atomic force microscopy probes.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: