Answers are grounded in this paper and cite their sources.
Background: Dual-energy CT (DECT) allows noninvasive detection of monosodium urate (MSU) crystal deposits and has become incorporated into the routine clinical evaluation for gout at many institutions over the past decade. Objective: To compare two time periods over the past decade in terms of radiologists' interpretations of DECT examinations performed for the evaluation of gout and subsequent clinical actions. Methods: This retrospective study included 100 consecutive adult patients who underwent DECT to evaluate for gout in each of two periods (periods beginning in March 2013 and September 2019). Examinations in 2013 used a second-generation DECT scanner (140 kV with 0.4 mm tin filter), and in 2019 used a third-generation DECT scanner (150 kV with 0.6 mm tin filter) that provides improved spectral separation. Original DECT reports were classified as positive, negative, or equivocal for MSU crystals indicative of gout. Joint aspirations occurring after the DECT examinations were recorded based on medical record review. A single radiologist performed a post hoc retrospective blinded image review, classifying examinations as positive, negative, or equivocal. Results: In 2013, 44.0% of DECT examinations were interpreted as positive, 23.0% as negative, and 33.0% as equivocal; in 2019, 37.0% were interpreted as positive, 47.0% as negative, and 16.0% as equivocal (p<.001). The frequency of joint aspiration after DECT was 14.0% in 2013 versus 2.0% in 2019 (p=.002), and after DECT examinations with negative interpretations was 17.4% in 2013 versus 2.1% in 2019 (p=.02). In post hoc assessment by a single radiologist, the distribution of interpretations in 2013 was positive in 49.0%, negative in 22.0%, and equivocal in 29.0%, and in 2019 was positive in 39.0%, negative in 50.0%, and equivocal in 11.0% (p<.001). Conclusion: When comparing DECT examinations performed for gout in 2013 and 2019, the frequency of equivocal interpretations was significantly lower in 2019, possibly related to interval technologic improvements. Negative examinations were less frequently followed by joint aspirations in 2019, possibly reflecting increasing clinical acceptance of the DECT results. Clinical Impact: The findings indicate an evolving role for DECT in the evaluation of gout following an institution's routine adoption of the technology for this purpose.
No takes yet. Share an insight, caveat, or question.
A 2022 study studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: