Why the study?
Does two-dimensional contrast echocardiography safely guide pericardiocentesis in patients with pericardial effusion?
Does two-dimensional contrast echocardiography safely guide pericardiocentesis in patients with pericardial effusion?
Two-dimensional contrast echocardiography using agitated saline is a feasible technique to confirm needle position and guide pericardiocentesis.
Answers are grounded in this paper and cite their sources.
Supports feasibility of contrast-guided pericardiocentesis in small series; leaves open safety and efficacy questions for prospective study.
The clinical application of two-dimensional contrast echocardiography to pericardiocentesis was investigated in 20 patients with pericardial effusion. Multiple views were obtained to determine the ideal needle entry route. During pericardiocentesis, after 5 to 10 mL of pericardial fluid was withdrawn, 3 to 5 mL of agitated saline solution was injected through the exploring needle into the pericardium and a cloud of echoes indicated the needle's position. Contrast echoes were observed in all 20 patients. The procedure was performed smoothly in all patients except two (10%): the exploring needle was inserted into the right atrium in one patient and into the right ventricle in the other patient. The former promptly underwent a surgical drainage procedure, and the latter a second pericardiocentesis successfully guided by contrast echocardiography. The pericardial fluid was simply, safely, and successfully aspirated in the other 18 patients. We conclude that two-dimensional contrast echocardiography is valuable for locating needle position, thus facilitating successful pericardiocentesis in clinical practice.
No takes yet. Share an insight, caveat, or question.
Chiang et al. (1993) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: