A novel fully transient RCR outflow boundary condition enables accurate 3D simulation of non-periodic blood flow and pressure in deformable arteries, improving patient-specific hemodynamic modeling.
Answers are grounded in this paper and cite their sources.
May improve accuracy of patient-specific hemodynamic simulations; leaves open clinical translation pending human validation.
The simulation of blood flow and pressure in arteries requires outflow boundary conditions that incorporate models of downstream domains. We previously described a coupled multidomain method to couple analytical models of the downstream domains with 3D numerical models of the upstream vasculature. This prior work either included pure resistance boundary conditions or impedance boundary conditions based on assumed periodicity of the solution. However, flow and pressure in arteries are not necessarily periodic in time due to heart rate variability, respiration, complex transitional flow or acute physiological changes. We present herein an approach for prescribing lumped parameter outflow boundary conditions that accommodate transient phenomena. We have applied this method to compute haemodynamic quantities in different physiologically relevant cardiovascular models, including patient-specific examples, to study non-periodic flow phenomena often observed in normal subjects and in patients with acquired or congenital cardiovascular disease. The relevance of using boundary conditions that accommodate transient phenomena compared with boundary conditions that assume periodicity of the solution is discussed.
No takes yet. Share an insight, caveat, or question.
A 2010 study studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: