Why the study?
Contact of blood with artificial surfaces triggers platelet activation, but platelet kinetics after V-V ECMO initiation and system exchange across different etiologies of acute lung failure were unclear.
Does V-V ECMO initiation and subsequent system exchange affect platelet kinetics and coagulation parameters differently across bacterial, viral, and COVID-19 pneumonia in adult patients?
Does V-V ECMO initiation and subsequent system exchange affect platelet kinetics and coagulation parameters differently across bacterial, viral, and COVID-19 pneumonia in adult patients?
Answers are grounded in this paper and cite their sources.
Platelet counts on V-V ECMO exhibit an initial disease-specific decline within 24 hours to a common steady state (~150/nL) by day 5 across all pneumonia types, and exposure to new artificial surfaces during an ECMO system exchange does not trigger further platelet consumption.
Contact of blood with artificial surfaces triggers platelet activation. The aim was to compare platelet kinetics after venovenous extracorporeal membrane oxygenation (V-V ECMO) start and after system exchange in different etiologies of acute lung failure. Platelet counts and coagulation parameters were analyzed from adult patients with long and exchange-free (≥8 days) ECMO runs (n = 330) caused by bacterial (n = 142), viral (n = 76), or coronavirus disease 2019 (COVID-19) (n = 112) pneumonia. A subpopulation requiring a system exchange and with long, exchange-free runs of the second oxygenator (≥7 days) (n = 110) was analyzed analogously. Patients with COVID-19 showed the highest platelet levels before ECMO implantation. Independent of the underlying disease and ECMO type, platelet counts decreased significantly within 24 hours and reached a steady state after 5 days. In the subpopulation, at the day of a system exchange, platelet counts were lower compared with ECMO start, but without differences between underlying diseases. Subsequently, platelets remained unchanged in the bacterial pneumonia group, but increased in the COVID-19 and viral pneumonia groups within 2-4 days, whereas D-dimers decreased and fibrinogen levels increased. Thus, overall platelet counts on V-V ECMO show disease-specific initial dynamics followed by an ongoing consumption by the ECMO device, which is not boosted by new artificial surfaces after a system exchange.
No takes yet. Share an insight, caveat, or question.
Lehle et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: