Key result
Hydrogoniometer arm assessment after stroke shows high interobserver reliability with smallest detectable differences of 6-22 degrees.
Observational (n=48)
2-arm randomized controlled trial (parent study)
Answers are grounded in this paper and cite their sources.
BACKGROUND: Goniometric measurements of hemiplegic arm joints must be reliable to draw proper clinical and scientific conclusions. Previous reliability studies were cross-sectional and based on small samples. Knowledge about the contributions of sources of variation to these measurement results is lacking. OBJECTIVE: The aims of this study were to determine the interobserver reliability of measurements of passive range of motion (PROM) over time, explore sources of variation associated with these measurement results, and generate smallest detectable differences for clinical decision making. DESIGN: This investigation was a measurement-focused study with a longitudinal design, nested within a 2-arm randomized controlled trial. METHODS: Two trained physical therapists assessed 7 arm movements at baseline and after 4, 8, and 20 weeks in 48 people with subacute stroke using a standardized protocol. One physical therapist performed the passive movement, and the other read the hydrogoniometer. The therapists then switched roles. The relative contributions of several sources of variation to error variance were explored with analysis of variance. RESULTS: /b> Interobserver reliability coefficients ranged from .89 to .97. The PROM measurements were influenced by error variance ranging from 31% to 50%. The participant × time interaction made the largest contribution to error variance, ranging from 59% to 81%. Smallest detectable differences were 6 to 22 degrees and were largest for shoulder movements. Limitations Verification of shoulder pain and hypertonia as sources of error variance led to a substantial number of unstable variance components, necessitating a simpler analysis. CONCLUSIONS: The assessment of PROM with a standardized protocol, a hydrogoniometer, and 2 trained physical therapists yielded high interobserver reliability indexes for all arm movements. Error variance made a large contribution to the variation in measurement results. The resulting smallest detectable differences can be used to interpret future hemiplegic arm PROM measurements with more confidence.
No takes yet. Share an insight, caveat, or question.
Jong et al. (2012) conducted an observational in Subacute stroke (n=48). Standardized hydrogoniometer passive range of motion assessment was evaluated on Interobserver reliability and sources of variation in passive range of motion (PROM) measurements (Reliability coefficients 0.89-0.97). Standardized hydrogoniometer assessment of arm PROM after stroke yielded high interobserver reliability, with error variance of 31%-50% and smallest detectable differences of 6-22 degrees.
Synapse has enriched 10 related papers. Consider them for comparative context: