Why the study?
To evaluate whether the cardiodynamicsgram, a novel noninvasive ECG method extracting dynamic ST-T segment information, can reflect anomalous functional information in CAD.
Does an ECG-based cardiodynamicsgram accurately diagnose coronary artery disease in patients with suspected CAD?
Does an ECG-based cardiodynamicsgram accurately diagnose coronary artery disease in patients with suspected CAD?
The ECG-based cardiodynamicsgram demonstrates good diagnostic accuracy for coronary artery disease and may serve as a noninvasive screening tool prior to CCTA.
BACKGROUND: The cardiodynamicsgram (CDG), a novel noninvasive method, extracts dynamic ST-T segment information from an electrocardiogram (ECG) through deterministic learning. HYPOTHESIS: The CDG can reflect anomalous functional information in coronary artery disease (CAD). METHODS: We retrospectively enrolled 456 patients with suspected CAD who underwent coronary computed tomography angiography (CCTA) from January 2020 to 2022, followed immediately by standard 12-lead ECG acquisition. Positivity for CAD were defined as CCTA ≥ 50% or CT-derived fractional flow reserve (CT-FFR) ≤ 0.8. A CDG value <0 was considered negative; otherwise, it was considered positive. We also evaluated the diagnostic performance of the CDG in the ECG-diagnosis-negative subgroup and in patients who had undergone invasive coronary angiography (ICA) after CCTA. RESULTS: Of 362 patients, 168 (46.41%) were positive for CAD, and 178 (49.17%) were men. The median age was 59 (52-66) years. The accuracy of the CDG in the diagnosis of CAD was 79.56%, with a sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC) of 75.60%, 82.99%, and 0.836 (95% CI: 0.794-0.878), respectively. Similarly, in the ECG-diagnosis-negative subgroup (n = 223), the accuracy of the CDG was 80.27%, with an AUC of 0.842 (95% CI: 0.790-0.895). Among the 11 patients with CAD confirmed by ICA, 10 were diagnosed positive by the CDG. Furthermore, the CDG values and CT-FFR were correlated (r = -.395; p < .001). CONCLUSIONS: The ECG-based CDG has relatively high specificity and accuracy for the diagnosis of CAD and reflects functional cardiac information to some extent. It has the potential to be used as a screening tool for suspected CAD patients before CCTA.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: