A constant-composition fluoride (F) titration method was used to measure the amount of leachable F deposited on tooth surfaces in vitro by a 1-min rinse with a 228-ppm F solution (12 mmol/l sodium fluoride). The mean F uptake was 0.23 +/- (SE) 0.07 microgram/cm2, corresponding to less than 0.2% of the F contained in the rinse. The present study describes a new F rinse system that consisted of two solutions. Solution A contained a soluble calcium salt and a buffer. Solution B contained sodium fluorosilicate, a complex fluoride salt. When solutions A and B were combined, the free F ions produced by hydrolysis of fluorosilicate caused precipitation of calcium fluoride during the 1-min application time. The F uptake produced by the two-solution rinse was 4.36 +/- 0.16 micrograms/cm2, which was approximately 19 times greater than that produced by the sodium F rinse with the same F content. Since the cariostatic effects from F rinses are believed to derive from their ability to deposit labile F in the oral cavity, the two-solution rinse may be more efficacious than the rinses currently in use.
No takes yet. Share an insight, caveat, or question.
Chow et al. (2009) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: