We have used a new millimeter-resolution MRI-based model of the human body to calculate the electromagnetic absorption in the head and neck for three experimental Yagi antennas suggested for handheld transceivers of a proposed 6-GHz personal communication network (PCN) system. The SAR distributions are obtained with a resolution of 1.974/spl times/1.974/spl times/1.5 mm for transceivers that are held against the ears and tilted forward by 33/spl deg/. The finite-difference time-domain technique is used to calculate the EM fields and SARs for the transceiver, antenna, and head and neck coupled region that is divided into 158/spl times/84/spl times/188 or nearly 2.5 million cells. The highlights of the numerical calculations are verified by means of a head-shaped experimental model made of tissue-equivalent materials simulating the electrical properties (/spl epsiv//sub r/,/spl sigma/) of the skull, brain, muscle, eyes, and ears developed for use at 6 GHz. Because of the proximity to the antenna, the highest SARs are obtained for the upper part of the ear. For a planned radiated power of 0.6 W, the peak SARs averaged over any 1 g of tissue defined as a tissue volume in the shape of a cube are on the order of 0.5-1.0 W/kg for two of the proposed antennas and considerably higher (2.06 W/kg) for the third antenna using a narrower off-axis reflector. Low SARs for the first two antennas are likely due to the shielding provided by the relatively wider strip reflector plates used for these antennas.