AIMS: The aim of this study was to investigate the reproducibility of intravascular optical coherence tomography (IVOCT) assessments, including a comparison to intravascular ultrasound (IVUS). Intra-observer and inter-observer variabilities of IVOCT have been previously described, whereas inter-institute reliability in multiple laboratories has never been systematically studied. METHODS AND RESULTS: In 2 independent laboratories with intravascular imaging expertise, 100 randomized matched data sets of IVOCT and IVUS images were analysed by 4 independent observers according to published consensus document definitions. Intra-observer, inter-observer, and inter-institute variabilities of IVOCT qualitative and quantitative measurements vs. IVUS measurements were assessed. Minor inter- and intra-observer variability of both imaging techniques was observed for detailed qualitative and geometric analysis, except for inter-observer mixed plaque identification on IVUS (κ = 0.70) and for inter-observer fibrous cap thickness measurement reproducibility on IVOCT (ICC = 0.48). The magnitude of inter-institute measurement differences for IVOCT was statistically significantly less than that for IVUS concerning lumen cross-sectional area (CSA), maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters (P < 0.001, P < 0.001, P < 0.001, P = 0.02, P < 0.001, and P = 0.01, respectively). Minor inter-institute measurement variabilities using both techniques were also found for plaque identification. CONCLUSION: In the measurement of lumen CSA, maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters by analysts from two different laboratories, reproducibility of IVOCT was more consistent than that of IVUS.
No takes yet. Share an insight, caveat, or question.
Gerbaud et al. (2015) conducted an observational in Intravascular imaging (IVOCT and IVUS) (n=100). Intravascular optical coherence tomography (IVOCT) vs. Intravascular ultrasound (IVUS) was evaluated on Intra-observer, inter-observer, and inter-institute variabilities of qualitative and quantitative measurements (lumen and stent CSA and diameters) (p=<0.001). IVOCT demonstrated lower inter-institute measurement differences than IVUS for lumen and stent cross-sectional areas and diameters.
Synapse has enriched 10 related papers. Consider them for comparative context: