Answers are grounded in this paper and cite their sources.
Transverse magnetization of spins diffusing in a bounded region in the presence of a constant field gradient is studied. We investigate the breakdown at short times of the much used formula for the Hahn echo amplitude in a constant gradient in unbounded space: ℳ(2τ)/ℳ(0)=exp(−2D0g2τ3/3). Here D0 is the diffusion constant in unbounded space and g is the field gradient multiplied by the gyromagnetic ratio. We find that this formula is replaced by ℳ(2τ)/ℳ(0)=exp[−2Deffg2τ3/3 +𝒪(D5/20g4τ13/2S/V)] with an effective diffusion coefficient Deff(2τ) =D0[1−α√D0τ(S/V) +...], where α is a constant and S/V is the surface to volume ratio of the bounded region. Breakdown is complex but we find that the interplay between a natural length scale lc=(g/D0)−1/3 and the geometry of the region governs the problem. The long-time behavior of the free induction decay and echo amplitude are then considered where pure exp[−const t] decay is expected. We consider some simple geometries and find in addition to the well-known result, ln‖M(z,t)‖∼−D0g2R4pt, valid for Rp≪lc (where Rp is the size of the confining space) that in the regime Rp≫lc the decay becomes ln‖M(z,t)‖∼−g2/3D1/30t. We then argue that this latter result should apply to more general geometries. We discuss implications for realistic experimental echo measurements and conclude that the g2/3D1/30 decay regime is hard to measure. Implications for the effect of edge enhancement in NMR microscopy are also discussed.
No takes yet. Share an insight, caveat, or question.
Swiet et al. (1994) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: