Why the study?
The study was conducted to evaluate the efficacy and safety of the stepwise mechanical transvenous lead extraction approach in patients with chronically implanted transvenous leads with a long dwell time.
Does the stepwise mechanical transvenous lead extraction approach provide high efficacy and safety in patients with chronically implanted transvenous leads with a long dwell time?
Does the stepwise mechanical transvenous lead extraction approach provide high efficacy and safety in patients with chronically implanted transvenous leads with a long dwell time?
The stepwise mechanical transvenous lead extraction approach is highly effective and safe for chronically implanted leads with a long dwell time.
Answers are grounded in this paper and cite their sources.
Should not yet change practice; leaves open prospective validation of stepwise mechanical extraction for long-dwell leads.
The aim of this study was to evaluate the efficacy and safety of the stepwise mechanical transvenous lead extraction approach in a patient population with chronically implanted transvenous leads with a long dwell time. From January 2014 till December 2018, all lead extractions with lead dwell time ≥5 years performed at our tertiary centre were retrospectively analysed. A total of 173 leads, from 78 patients (median age 68 years; 81% male) with a median dwell time of 9 years (interquartile range [IQR] 5) were extracted, with three or more leads in 42% of the patients. Right atrial leads: 41%; right ventricular pacing leads: 16%; implantable cardioverter-defibrillator (ICD) leads: 31% (72% dual coil); coronary sinus leads: 12%. The majority (75%) of the leads had an active fixation. Most frequent indication for extraction was pocket infection/erosion (76%). Overall clinical success was 97%, and complete procedural success was 93%. Venous patency, assessed with venous angiography, was well preserved in 93% of the cases. The overall procedural complication rate was 3.8% (2.6% major and 1.3% minor). Despite the complexity of the population and a very long dwell time (median 9 years), a clinical success rate of 97% was achieved with the stepwise mechanical approach. Analysis of impeding progression of pectoral extraction suggests that dense fibrosis and sharp lead curvature in the transvenous trajectory pose a challenge. Complication rate was low, and acute venous patency was generally well preserved.
No takes yet. Share an insight, caveat, or question.
Lensvelt et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: