Why the study?
Are haemodynamic measurements during exercise testing reproducible for assessing left ventricular function in patients suspected of arteriosclerotic heart disease?
Are haemodynamic measurements during exercise testing reproducible for assessing left ventricular function in patients suspected of arteriosclerotic heart disease?
Haemodynamic measurements during exercise testing using pulmonary and radial artery catheters provide a safe and reproducible estimation of left ventricular function.
Answers are grounded in this paper and cite their sources.
Supports reproducible LV function assessment via exercise haemodynamics; leaves open prospective validation before clinical adoption.
In order to estimate the value of haemodynamic parameters in assessing impaired left ventricular function the reproducibility of haemodynamic measurements were investigated at rest and during supine exercise on a bicycle ergometer in fifty-one patients suspected of arteriosclerotic heart disease by means of a Swan-Ganz pulmonary artery thermodilution catheter and a radial artery catheter. Furthermore the minimal significant (P less than 0.05) change from rest to exercise was determined. In conclusion we found that haemodynamic measurements during exercise testing estimate left ventricular function in a safe and reproducible manner. A rise in pulmonary capillary wedge pressure (PCWP) of only 0.9 kPa during exercise was significant, whereas changes in stroke volume index (SVI) were considered significant only when exceeding 9 ml/m2.
No takes yet. Share an insight, caveat, or question.
Bille‐Brahe et al. (1981) studied this question.