Answers are grounded in this paper and cite their sources.
A rapid and sensitive high-performance LC-MS/MS method was developed and validated for the simultaneous quantification of codeine and its metabolite morphine in human plasma using donepezil as an internal standard (IS). Following a single liquid-liquid extraction with ethyl acetate, the analytes were separated using an isocratic mobile phase on a C(18 )column and analyzed by MS/MS in the selected reaction monitoring mode using the respective [M+H](+ )ions, mass-to-charge ratio (m/z) 300/165 for codeine, m/z 286/165 for morphine and m/z 380/91 for IS. The method exhibited a linear dynamic range of 0.2-100/0.5-250 ng/mL for codeine/morphine in human plasma, respectively. The lower LOQs were 0.2 and 0.5 ng/mL for codeine and its metabolite morphine using 0.5 mL of human plasma. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated LC-MS/MS method was applied to a pharmacokinetic study in which healthy Chinese volunteers each received a single oral dose of 30 mg codeine phosphate.
No takes yet. Share an insight, caveat, or question.
Liao et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: