Answers are grounded in this paper and cite their sources.
Background: Endotracheal intubation is part of general anesthesia. The endotracheal cuff situated near the end of the tube is inflated following successful intubation (above the carina) to secure the airway. A critical function of the endotracheal tube (ETT) cuff during general anesthesia is to seal the airway thus preventing aspiration of pharyngeal contents into the trachea and leaks during positive pressure ventilation. From the literature, we know that excessive cuff pressure decreases tracheal capillary perfusion which has the potential to lead to endothelial necrosis, while insufficient cuff pressure leads to pulmonary aspiration of oro-pharyngeal contents and leads to ventilator-associated pneumonia and pulmonary pneumonitis. Methodology: All the patients above the age of 18 years who presented to The Aga Khan University Hospital, Nairobi for elective surgical procedures under general anesthesia and requiring endotracheal intubation for the surgical procedure were included in the audit. Patients were induced and intubated according to routine practice by the attending anesthesiologist and the cuff was subsequently inflated by the anesthetic assistant, anesthesia resident, instructor, or consultant anesthesiologist. Patients were maintained with volatile anesthetic agents or total intravenous anesthesia in a mixture of oxygen and air according to the anesthesiologist’s choice. The volume of the air used to inflate the cuff was recorded and the intra-cuff pressure was measured by one of the investigators after securing the endotracheal tube (before positioning the patient) with an aneroid manometer connected to the pilot balloon of the ETT cuff. Results: The volume of air used to inflate the endotracheal cuff was in the range of 3ml and 15ml with the mean volume being 7.64 ml, median of 8ml, and mode of 10ml. The resultant cuff pressure ranged between 10 cmH₂O to 110 cmH₂O with a median of 40 ml and mode of 22 ml. Overall 14% of the total patients had intra-cuff pressure of less than normal which is below 20 cmH₂O, 23% of patients had normal cuff pressure between 20 to 30 cmH₂O, and 63% had more than normal pressure which was more than 30 cmH₂O. Conclusion: The average volume of air inflated for the endotracheal cuff was 7.64 ml and the cuff pressure was 46.71 cmH₂O. Recommendations: The endotracheal tube cuff is inflated under the guidance of a manometer to a target pressure of 20-30 cmH₂O.
No takes yet. Share an insight, caveat, or question.
Samina Mir (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: