Key result
Sphere-9 coronary sinus ablation achieves 100% bidirectional mitral isthmus block after failed endocardial ablation.
Why the study?
Mitral isthmus ablation is challenging due to anatomical and vascular factors, motivating the evaluation of a lattice-tip dual-energy catheter for radiofrequency ablation in the coronary sinus after failed endocardial ablation.
Does CS-based RF ablation using a lattice-tip dual-energy catheter achieve bidirectional mitral annular block in patients with drug-refractory AF/AFL after failed endocardial ablation?
Case Report (n=6)
Does CS-based RF ablation using a lattice-tip dual-energy catheter achieve bidirectional mitral annular block in patients with drug-refractory AF/AFL after failed endocardial ablation?
Hybrid epicardial mitral isthmus ablation via the coronary sinus using the Sphere-9 catheter with stepwise RF escalation is feasible and safe for achieving bidirectional block when endocardial ablation fails.
Hypothesis-generating for adjunctive CS RF after failed endocardial mitral isthmus ablation; leaves open safety and durability pending prospective trials.
Background Mitral isthmus (MI) ablation is frequently performed for persistent atrial fibrillation (AF) and mitral annular atrial flutter (AFL), but bidirectional block remains challenging because of tissue thickness, fibrosis, epicardial coronary sinus (CS) connections, and proximity to vascular structures. Objectives To describe the first case series using lattice-tip dual-energy Sphere-9 catheter to deliver temperature-controlled radiofrequency (RF) energy within the CS as an adjunctive epicardial strategy for bidirectional MI block after failed endocardial ablation. Methods Six consecutive patients with drug-refractory AF or AFL underwent endocardial ablation combining pulsed field ablation (PFA) and RF energy. When bidirectional MI block could not be achieved endocardially, CS-based RF ablation was performed using a stepwise temperature-escalation strategy, initiated at 50 °C for 3 seconds and titrated in 5 °C and 2-second increments to a maximum of 60–70 °C for 7 seconds. PFA was avoided within the CS given concern for vasospasm of adjacent coronary structures. Bidirectional block was confirmed by activation sequence reversal and absence of inducible arrhythmias. Results Bidirectional MI block was achieved in all six patients. Three required escalation to 70 °C for 7 seconds for persistent block; in one, initial 60 °C ablation produced only transient block that recovered. No coronary artery injury, pericardial tamponade, or CS perforation was observed. At latest rhythm documentation, all patients remained in normal sinus rhythm. Conclusions Hybrid epicardial MI ablation via the CS using the Sphere-9 catheter with stepwise RF escalation is feasible and appears safe when endocardial ablation is insufficient. Prospective studies are warranted.
No takes yet. Share an insight, caveat, or question.
Rodriguez-Riascos et al. (2026) conducted a case report in Drug-refractory atrial fibrillation or atrial flutter (n=6). Coronary sinus-based radiofrequency ablation using the lattice-tip dual-energy Sphere-9 catheter was evaluated on Bidirectional mitral isthmus block. Coronary sinus-based radiofrequency ablation using the Sphere-9 catheter achieved bidirectional mitral isthmus block in 100% (6/6) of patients after failed endocardial ablation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: