Answers are grounded in this paper and cite their sources.
Electrical parameters such as total equivalent capacitance, dielectric capacitance, and average discharge power of a dielectric barrier discharge (DBD)-cold atmospheric plasma (CAP) setup have been determined and their dependency on the applied voltage, air gap, and ground arrangement have been investigated. Considering a more practical scenario of DBD-CAP application in material processing and biomedical fields, three different ground arrangements: (i) bare ground, (ii) glass slide covered ground and (iii) water in a petri dish on the ground electrode have been considered in this study. The electrical parameters are determined by interpreting the charge-voltage (Q-V) plot of the DBD-CAP obtained experimentally. The value of effective dielectric capacitance ( ζ d ) determined from Q-V plot at a lower applied voltage is less, and approaches the geometrically calculated value ( C d ) at higher applied voltage which signifies the DBD discharge occurs from the partial area of the electrode surface. Discharge power and discharge efficiency increase with the applied voltage ( V a ). Empirical fit of the obtained discharge power shows the increase is proportional to ( V a − B ) 2 , where the value of constant B is close to the value of threshold voltage for the discharge.
No takes yet. Share an insight, caveat, or question.
Gohain et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: